Instructions manual DS series
17
Scanning with CROSSED beams: where several photoreceivers
are illuminated by the beam of a single photoemitter (this mode
activates a series of photoreceivers and one photoemitter
contemporarily, during the scanning cycle). The scanning with
crossed beams can be used for the detection of objects with small
dimensions and, in particular, for the detection of transparent
objects. The minimum object that can be detected is 0.5 mm
(that represents the minimum resolution of the device in this mode).
The real resolution of the device also depends on the object’s
position in the detection field, as shown below (Fig.9).
The analog output is not activated in this mode.
Fig. 9